Inhaltsverzeichnis   MOBOTIX Online-Hilfe

Message Events

The Message Events dialog contains all event sensors that can trigger a camera action based on incoming messages.

Avoiding False Alarms

Meta Events

In order to filter events, the camera provides an Event Logic: This dialog allows linking events to create logic events only if the linked events occur in a certain sequence and within the specified time frame. Another possibility to filter events is the Event Counter: It creates an event only if a certain number of events occurs within the specified time frame.


General Settings

Option Description
Event Dead Time

The event dead time defines a period of time (0 .. 3600 s) after an event during which no new events from the same profile are recognized.

By defining an event dead time you can avoid, for example, that a complex action (person walks through the active image area) triggers multiple events.

Description of Event Sensor Types

Event Sensor Type Description
Network Message The camera can trigger an event when it receives an IP notification via TCP/IP:
  • Set the port at which you expect the notification.
  • Select the type of check:
    String Compare The event is triggered if the received text is identical to the text entered here.
    Regular Expression The event is triggered if the received text matches the regular expression entered here.
  • Enter the text or the regular expression.
  • Set the list of IP addresses of valid senders (separated by spaces). Use the following regular expression syntax to check the port number of the sender: /^10.1.0.123:42000/

Note: This feature is not available for Web and Basic models.

MxMessageSystem The camera can trigger an event when it receives a message via the MxMessageSystem from the MxBus or the network. Set the MxMessageSystem Name that is used to trigger the event. Note that you can define several message events for the same MxMessageSystem name. A valid MxMessageSystem-Name must start with a letter, it must not contain spaces, tabs or the characters "/", "%" or ".", the name is case-sensitive and the maximum length is 31 characters.
Serial COM In The camera can trigger an event when it receives a message via the serial interface (RS232).
  • Select the type of check:
    String Compare The event is triggered if the received text is identical to the text entered here.
    Regular Expression The event is triggered if the received text matches the regular expression entered here.
    Binary Compare The event is triggered if the received text is identical to the binary value entered here.
  • Enter the text or the regular expression.
Notes:

If you perform a binary comparison, you need to enter special characters as hex notations according to the ASCII code.

Example:

Character Hexadecimal notation
? %3F
= %3D

If you have selected a timestamp when setting up the serial interface, this timestamp is part of the message and will also be analyzed. If you want to filter according to the actual contents of the message, you can use the following regular expressions:

Filtering according to any part of the message ^[0-9]{4}-[0-9]{2}-[0-9]{2} [0-9]{2}:[0-9]{2}:[0-9]{2} .*<expression>
Filtering according to the start of the message ^[0-9]{4}-[0-9]{2}-[0-9]{2} [0-9]{2}:[0-9]{2}:[0-9]{2} <expression>
Filtering according to the end of the message ^[0-9]{4}-[0-9]{2}-[0-9]{2} [0-9]{2}:[0-9]{2}:[0-9]{2} .*<expression>$

Remember to replace <expression> by the expression you want to use for filtering.

Examples:

Message contains "rror" ^[0-9]{4}-[0-9]{2}-[0-9]{2} [0-9]{2}:[0-9]{2}:[0-9]{2} .*rror
Message starts with one or more letters, followed by a digit ^[0-9]{4}-[0-9]{2}-[0-9]{2} [0-9]{2}:[0-9]{2}:[0-9]{2} [A-Za-z]+[0-9]
Message ends on "Error!" ^[0-9]{4}-[0-9]{2}-[0-9]{2} [0-9]{2}:[0-9]{2}:[0-9]{2} Error!$

Konfiguration sichern

Klicken Sie auf Setzen, um die Einstellungen zu aktivieren und bis zum nächsten Neustart der Kamera zu sichern.

Klicken Sie auf Voreinstellung, um diesen Dialog auf die werkseitigen Voreinstellungen zurückzusetzen (dieser Button wird nicht in allen Dialogen angezeigt).

Klicken Sie auf Wiederherstellen, um alle Änderungen seit dem letzten permanenten Speichern der Konfiguration zu verwerfen.

Beenden Sie den Dialog durch Klick auf Schließen. Hierbei wird geprüft, ob Änderungen der Gesamtkonfiguration vorliegen. Ist dies der Fall, werden Sie gefragt, ob die Gesamtkonfiguration dauerhaft gesichert werden soll.